Inspection [09/2015 - ]: Procedure
- INSPECT CLOCK ASSEMBLY
- Check the illumination.
Apply battery voltage to the connector and check the illumination condition.
OK
Measurement Condition Specified Condition Battery positive (+) → Terminal 1 (B)
Battery positive (+) → Terminal 2 (ACC)
Battery negative (-) → Terminal 7 (E)
Battery negative (-) → Terminal 8 (ILL-)Illuminates If the result is not as specified, replace the clock assembly.
TEXT IN ILLUSTRATION* a Component without harness connected
(Clock Assembly)
- Check the illumination.