Component Operating Range
C0571
| Both of the following conditions are met | - |
| Pressure sensor 1 stuck failure detection trigger signal is met for 0.018 seconds or more | Off |
| Power supply voltage ratio of ACC and VCM | 0.05 or more |
HINT:
The power supply voltage ratio is the ratio of the voltage of ACC and VCM.
C0572
| Borh of the following conditions are met | - |
| Pressure sensor 1 stuck failure detection trigger signal is met for 0.018 seconds or more | Off |
| Power supply voltage ratio of ACC and VCM | 0.905 or less |
HINT:
The power supply voltage ratio is the ratio of the voltage of ACC and VCM.
C0574 (CASE 1)
| Difference between the current accumulator pressure and the accumulator pressure when braking starts | 0.5 MPa (5.1 kgf/cm2 , 73 psi) or more |
C0574 (CASE 2)
| Both of the following conditions are met | - |
| Pressure sensor 1 stuck detection trigger signal | Off |
| Power supply voltage ratio of ACC and VCM | 0.905 or less |
HINT:
The power supply voltage ratio is the ratio of the voltage of ACC and VCM.
C121A
| Accumulator pressure sensor noise 1 | Off |
C14D0
| Pressure sensor power supply voltage (VCM1) | Higher than 4.7 V, and less than 5.3 V |