Typical Enabling Conditions
HINT:
SAE code only.
C0562, P057C, P057D, P057E, P05DD, P05DE, AND P05DF
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): EEPROM malfunction C0597 (Case 2): Lost communication C0597 (Case 3 and 5): CPU malfunction C0597 (Case 4): IC malfunction |
| Either of the following conditions is met | A or B |
| A. Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 8.5 V |
| Brake system voltage 1 monitor value | Valid |
| B. Both of the following conditions are met | - |
| Brake system voltage 2 | Higher than 8.5 V |
| Brake system voltage 2 monitor value | Valid |
C124B
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): EEPROM malfunction C0597 (Case 2): Lost communication C0597 (Case 3 and 5): CPU malfunction C0597 (Case 4): IC malfunction P057C: Brake pedal stroke sensor assembly sensor 1 open circuit P057D: Brake pedal stroke sensor assembly sensor 1 circuit high P05DD: Brake pedal stroke sensor assembly sensor 2 open circuit P05DE: Brake pedal stroke sensor assembly sensor 2 circuit high P05E0: Brake pedal stroke sensor assembly "A"/"B" correlation |
| All of the following conditions are met | A, B and C |
| A. Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 8.5 V |
| Brake system voltage 1 monitor value | Valid |
| 2. Both of the following conditions are met | - |
| Brake system voltage 2 | Higher than 8.5 V |
| Brake system voltage 2 monitor value | Valid |
| B. Brake pedal position sensor fail (P057C, P05DD, P057D, P05DE, P05E0) | Not detected |
| C. Master cylinder pressure sensor fail (C122C) | Not detected |
C1392
| Monitor runs whenever the following DTCs are not stored | None |
| Vehicle speed | 40 km/h (24.86 mph) or more |
P05E0
| Monitor runs whenever the following DTCs are not stored | C0562: Brake pedal stroke sensor assembly voltage circuit/open C0597 (Case 1): EEPROM malfunction C0597 (Case 2): Lost communication C0597 (Case 3 and 5): CPU malfunction C0597 (Case 4): IC malfunction C124B: Brake pedal stroke sensor assembly invalid data C1392: Brake pedal stroke sensor assembly learning not complete P057C: Brake pedal stroke sensor assembly sensor 1 open circuit P057D: Brake pedal stroke sensor assembly sensor 1 circuit high P057E: Brake pedal stroke sensor assembly sensor 1 intermittent/erratic P05DD: Brake pedal stroke sensor assembly sensor 2 open circuit P05DE: Brake pedal stroke sensor assembly sensor 2 circuit high P05DF: Brake pedal stroke sensor assembly sensor 2 intermittent/erratic |
| All of the following conditions are met | A, B and C |
| A. Master cylinder pressure sensor fail (C122C) | Not detected |
| B. Brake pedal position sensor fail (C124B, P057C, P05DD, P057D, P05DE) | Not detected |
| C. Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 8.5 V |
| Brake system voltage 1 monitor value | Valid |
| 2. Both of the following conditions are met | - |
| Brake system voltage 2 | Higher than 8.5 V |
| Brake system voltage 2 monitor value | Valid |