Inspection [10/2017 - ]: Procedure
- INSPECT LUGGAGE DOOR OPENING CANCEL SWITCH ASSEMBLY
- Check the resistance.
*a Component without harness connected
(Luggage Door Opening Cancel Switch Assembly)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition G74-2(B) - G74-1(L) Switch on Below 1 Ω G74-2(B) - G74-1(L) Switch off 10 kΩ or higher HINT:
If the result is not as specified, replace the luggage door opening cancel switch assembly.
- Measure the resistance according to the value(s) in the table below.
- Check the resistance.