Inspection [10/2017 - ]: Procedure
- INSTALL DOOR CONTROL SWITCH
- Check the resistance.
*a Component without harness connected
(Door Control Switch)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition L16-4 (CSW) - L16-1(E) Switch on Below 1 Ω L16-4 (CSW) - L16-1(E) Switch off 10 kΩ or higher HINT:
If the result is not as specified, replace the door control switch.
- Measure the resistance according to the value(s) in the table below.
- Inspect the illumination operation.
- Apply auxiliary battery voltage to the door control switch connector, and check that the door control switch LED illuminates.
OK
Tester Connection Specified Condition L16-3 (ILL+) - Auxiliary battery positive (+)
L16-2 (ILL-) - Auxiliary battery negative (-)LED illuminates HINT:
If the result is not as specified, replace the door control switch.
- Apply auxiliary battery voltage to the door control switch connector, and check that the door control switch LED illuminates.
- Check the resistance.