Inspection [10/2017 - ]: Procedure
- INSPECT TRUNK AND FUEL SWITCH ASSEMBLY
- Check the resistance.
*a Component without harness connected
(Trunk and Fuel Switch Assembly)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition G73-2 (B) - G73-3 (L) Switch on Below 1 Ω G73-2 (B) - G73-3 (L) Switch off 10 kΩ or higher HINT:
If the result is not as specified, replace the trunk and fuel switch assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect the illumination operation.
- Apply auxiliary battery voltage to the trunk and fuel switch assembly connector, and check that the trunk and fuel switch assembly LED illuminates.
OK
Tester Connection Specified Condition G73-1 (ILL+) - Auxiliary battery positive (+)
G73-5 (ILL-) - Auxiliary battery negative (-)LED illuminates HINT:
If the result is not as specified, replace the trunk and fuel switch assembly.
- Apply auxiliary battery voltage to the trunk and fuel switch assembly connector, and check that the trunk and fuel switch assembly LED illuminates.
- Check the resistance.