Entire Combination Meter does not Operate [10/2020 - 11/2021]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the G34*1 or G162*2 combination meter assembly connector.
- *1: w/o Advanced Drive
- *2: w/ Advanced Drive
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/O ADVANCED DRIVETester Connection Condition Specified Condition G34-31 (ES) - Body ground Always Below 1 Ω W/ ADVANCED DRIVETester Connection Condition Specified Condition G162-2 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
W/O ADVANCED DRIVETester Connection Switch Condition Specified Condition G34-21 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V G34-22 (B) - Body ground Power switch off 11 to 14 V W/ ADVANCED DRIVETester Connection Switch Condition Specified Condition G162-6 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V G162-5 (B) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2020 - 11/2021]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the G34*1 or G162*2 combination meter assembly connector.