Entire Combination Meter does not Operate [10/2017 - 10/2020]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the G34 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G34-31 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition G34-21 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V G34-22 (B) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2017 - 10/2020]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR