Fuel Lid Opener System Operation Message Display Malfunction [10/2023 - ]: Procedure
- INSPECT COMBINATION METER ASSEMBLY (OUTPUT VOLTAGE)
- Disconnect the A56 ECM connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition A56-59 (LSTM) - Body ground Ignition switch off 11 to 14 V Result
Proceed to OK NG
Result:
NG
See step 5
Result:
OK
See step 2
- CHECK VEHICLE TYPE
Result:
B
See step 4
Result:
A
See step 3
- INSPECT COMBINATION METER ASSEMBLY (INPUT WAVEFORM)
*a Component with harness connected
(Combination Meter Assembly)- Connect the ECM connector.
- Operate the fuel lid opener switch.
- Check the signal waveform according to the condition(s) in the table below.NOTE:
Perform the inspection from the back of the connector with the connector connected.
- Waveform 1:
Item Condition Tester connection G162-28 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Vehicle condition "Ready to Refuel" displayed on multi-information display - Waveform 2:
Item Condition Tester connection G162-28 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Vehicle condition "Close Fuel Lid" displayed on multi-information display HINT:
This waveform is output when the fuel lid opener switch is operated if the fuel lid is open and any of the following conditions are met:
- The vehicle has been driven for 1 km (0.6 mile) or more at a speed of 50 km/h (31 mph) or more.
- 30 minutes or more have elapsed since the fuel lid opener switch was operated.
- Waveform 3:
Item Condition Tester connection G162-28 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Vehicle condition "Please Wait Fuel Door Opening" displayed on multi-information display HINT:
This waveform is output when the internal pressure of the fuel tank is higher than the ambient pressure when the fuel lid opener switch is operated.
Result
Result Proceed to All of the waveforms are output normally A A waveform is not output normally B - Waveform 1:
Result:
A
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2023 - ]
Result:
B
REPLACE ECM. Refer to REMOVAL [10/2023 - ]
- INSPECT COMBINATION METER ASSEMBLY (INPUT WAVEFORM)
*a Component with harness connected
(Combination Meter Assembly)- Connect the ECM connector.
- Operate the fuel lid opener switch.
- Check the signal waveform according to the condition(s) in the table below.NOTE:
Perform the inspection from the back of the connector with the connector connected.
- Waveform 1:
Item Condition Tester connection G209-28 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Vehicle condition "Ready to Refuel" displayed on multi-information display - Waveform 2:
Item Condition Tester connection G209-28 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Vehicle condition "Close Fuel Lid" displayed on multi-information display HINT:
This waveform is output when the fuel lid opener switch is operated if the fuel lid is open and any of the following conditions are met:
- The vehicle has been driven for 1 km (0.6 mile) or more at a speed of 50 km/h (31 mph) or more.
- 30 minutes or more have elapsed since the fuel lid opener switch was operated.
- Waveform 3:
Item Condition Tester connection G209-28 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Vehicle condition "Please Wait Fuel Door Opening" displayed on multi-information display HINT:
This waveform is output when the internal pressure of the fuel tank is higher than the ambient pressure when the fuel lid opener switch is operated.
Result
Result Proceed to All of the waveforms are output normally A A waveform is not output normally B - Waveform 1:
Result:
A
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2023 - ]
Result:
B
REPLACE ECM. Refer to REMOVAL [10/2023 - ]
- CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER ASSEMBLY)
- *1: w/ Front LiDAR Sensor
- *2: w/o Front LiDAR Sensor
- Disconnect the A56 ECM connector.
- Disconnect the G162*1 or G209*2 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/ FRONT LIDAR SENSORTester Connection Condition Specified Condition A56-59 (LSTM) - G162-28 (LST1) Always Below 1 Ω A56-59 (LSTM) or G162-28 (LST1) - Body ground Always 10 kΩ or higher W/O FRONT LIDAR SENSORTester Connection Condition Specified Condition A56-59 (LSTM) - G209-28 (LST1) Always Below 1 Ω A56-59 (LSTM) or G209-28 (LST1) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR