LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2021 >> LS 500 Base, AWD >> Repair and Diagnosis >> Brakes >> Mechanical - Hydraulic >> Electronically Controlled Brake System (W/O Vacuum Brake Booster) - Diagnostic Codes (3 Of 3), Circuit & Symptom Tests >> ELECTRONICALLY CONTROLLED BRAKE SYSTEM (w/o Vacuum Brake Booster) >> DTC C1464: Front Speed Sensor RH Circuit; DTC C1465: Front Speed Sensor LH Circuit [12/2017 - 10/2020] >> Description

DTC C1464: Front Speed Sensor RH Circuit; DTC C1465: Front Speed Sensor LH Circuit [12/2017 - 10/2020]: Description

DTC No. Detection Item INF Code DTC Detection Condition Trouble Area Note
C1464 Front Speed Sensor RH Circuit 251
252
253
254
255
262
  • INF Code: 251
    • At a vehicle speed of 10 km/h (6 mph) or more, an open or short signal occurs in the speed sensor circuit.
  • INF Code: 252
    • A malfunction occurs in 2 or more wheels.
  • INF Code: 253
    • An open is detected in the speed sensor signal circuit for 0.5 seconds or more.
  • INF Code: 254
    • Instantaneous interruption of sensor signal from the malfunctioning wheel occurs 255 times or more.
  • INF Code: 255
    • Frequency of 2.4 kHz or more is input.
  • INF Code: 262
    • Either of the following is detected:
      1. When IG1 voltage is 9.5 V or more, sensor supply voltage drops for 0.5 seconds or more.
      2. When IG1 voltage is 9.5 V or more, sensor supply voltage fluctuates for 60 seconds or more.
  • INF Code: 251, 252, 253, 254
    • Open or short in speed sensor
    • Improperly installed speed sensor, or abnormal clearance between sensor and rotor
    • Open or short in wire harness
    • Improperly connected connector, deformation or corrosion of terminals
    • Resistance in speed sensor circuit
    • Front speed sensor RH
    • skid control ECU assembly
  • INF Code: 255
    • Open or short in speed sensor
    • Open or short in wire harness
    • Front speed sensor RH
    • Front speed sensor rotor RH (Front axle hub sub-assembly RH)
  • INF Code: 262
    • Open or short in wire harness
    • skid control ECU assembly
-
C1465 Front Speed Sensor LH Circuit 264
265
266
267
268
275
  • INF Code: 264
    • At a vehicle speed of 10 km/h (6 mph) or more, an open or short signal occurs in the speed sensor circuit.
  • INF Code: 265
    • A malfunction occurs in 2 or more wheels.
  • INF Code: 266
    • An open is detected in the speed sensor signal circuit for 0.5 seconds or more.
  • INF Code: 267
    • Instantaneous interruption of sensor signal from the malfunctioning wheel occurs 255 times or more.
  • INF Code: 268
    • Frequency of 2.4 kHz or more is input.
  • INF Code: 275
    • Either of the following is detected:
      1. When IG1 voltage is 9.5 V or more, sensor supply voltage drops for 0.5 seconds or more.
      2. When IG1 voltage is 9.5 V or more, sensor supply voltage fluctuates for 60 seconds or more.
  • INF Code: 264, 265, 266, 267
    • Open or short in speed sensor
    • Improperly installed speed sensor, or abnormal clearance between sensor and rotor
    • Open or short in wire harness
    • Improperly connected connector, deformation or corrosion of terminals
    • Resistance in speed sensor circuit
    • Front speed sensor LH
    • skid control ECU assembly
  • INF Code: 268
    • Open or short in speed sensor
    • Open or short in wire harness
    • Front speed sensor LH
    • Front speed sensor rotor LH (Front axle hub sub-assembly LH)
  • INF Code: 275
    • Open or short in wire harness
    • skid control ECU assembly
-

HINT: 

DTC DETECTION CONDITIONS: C1464 INF CODE: 262

  Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition IG1 terminal voltage is 9.5 V or more ◦ ◦
Malfunction Status The sensor power supply voltage is low ◦ -
The sensor power supply voltage is unstable - ◦
Detection Time 0.5 seconds or more 60 seconds or more
Number of Trips 1 trip 1 trip
DTC DETECTION CONDITIONS: C1465 INF CODE: 275

  Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition IG1 terminal voltage is 9.5 V or more ◦ ◦
Malfunction Status The sensor power supply voltage is low ◦ -
The sensor power supply voltage is unstable - ◦
Detection Time 0.5 seconds or more 60 seconds or more
Number of Trips 1 trip 1 trip