Odo/Trip Switch Malfunction [01/2017 - ]: Procedure
- READ VALUE USING TECHSTREAM (ODO/TRIP CHANGE SW)
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [01/2017 - 06/2019] , or refer to DATA LIST / ACTIVE TEST [06/2019 - ]
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ODO/TRIP Change SW ODO/TRIP switch OFF or ON OFF: ODO/TRIP switch released
ON: ODO/TRIP switch pushed- Body Electrical > Combination Meter > Data List
Tester Display ODO/TRIP Change SW OK
ODO/TRIP switch condition displayed on the Techstream changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [01/2017 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT TRIP SWITCH
- Remove the trip switch.
Refer to REMOVAL [01/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
- Inspect the trip switch.
Refer to INSPECTION [01/2017 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [01/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
Result:
OK
See step 3
- Remove the trip switch.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
- Disconnect the P25 combination meter assembly connector.
- Disconnect the P3 trip switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition P25-4 (ODO) - P3-4 (A/B) Always Below 1 Ω P25-26 (SW3) - P3-7 (E) Always Below 1 Ω P25-4 (ODO) or P3-4 (A/B) - Other terminals and body ground Always 10 kΩ or higher P25-26 (SW3) or P3-7 (E) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [01/2017 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR