Hybrid System Indicator Malfunction [01/2017 - ]: Procedure
- READ VALUE USING TECHSTREAM (HV SYSTEM INDICATOR)
- Using the Techstream, perform the Active Test.
Refer to DATA LIST / ACTIVE TEST [01/2017 - 06/2019] , or refer to DATA LIST / ACTIVE TEST [06/2019 - ]
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note HV System Indicator Hybrid system indicator value Min.: -101%, Max.: 511% -101 to 511% - Body Electrical > Combination Meter > Data List
Tester Display HV System Indicator OK
Hybrid system indicator value displayed on the Techstream is almost the same as the hybrid system indicator indication.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [01/2017 - ]
Result:
NG
See step 2
- Using the Techstream, perform the Active Test.
- CHECK COMBINATION METER ASSEMBLY
- Replace the combination meter assembly.
Refer to REMOVAL [01/2017 - ]
- Check that the operation of the hybrid system indicator returns to normal.
OK
The operation of the hybrid system indicator returns to normal.
Result
Proceed to OK NG
Result:
OK
END (COMBINATION METER ASSEMBLY IS DEFECTIVE)
Result:
NG
REPLACE HYBRID VEHICLE CONTROL ECU. Refer to REMOVAL [01/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
- Replace the combination meter assembly.