Hazard Warning Switch Circuit [03/2017 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [03/2017 - 04/2020] , or refer to DATA LIST / ACTIVE TEST [04/2020 - 05/2023] , or refer to DATA LIST / ACTIVE TEST [05/2023 - ]
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch OFF or ON OFF: Hazard warning signal switch off
ON: Hazard warning signal switch on- Body Electrical > Combination Meter > Data List
Tester Display Hazard Flasher Switch OK
Normal condition listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [03/2017 - 05/2023] , or refer to PROBLEM SYMPTOMS TABLE [05/2023 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)
- Remove the integration control and panel assembly (hazard warning signal switch).
Refer to REMOVAL [03/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
- Inspect the integration control and panel assembly (hazard warning signal switch).
Refer to INSPECTION [03/2017 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE INTEGRATION CONTROL AND PANEL ASSEMBLY (HAZARD WARNING SIGNAL SWITCH). Refer to REMOVAL [03/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
Result:
OK
See step 3
- Remove the integration control and panel assembly (hazard warning signal switch).
- CHECK HARNESS AND CONNECTOR (INTEGRATION CONTROL AND PANEL ASSEMBLY [HAZARD WARNING SIGNAL SWITCH] - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the P84 integration control and panel assembly (hazard warning signal switch) connector.
- Disconnect the P26 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition P84-6 (HAZ) - P26-2 (HZSW) Always Below 1 Ω P84-3 (GND) - Body ground Always Below 1 Ω P84-6 (HAZ) or P26-2 (HZSW) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [03/2017 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR