Operating Light Control Rheostat does not Change Light Brightness [07/2020 - ]: Procedure
- READ VALUE USING TECHSTREAM (LIGHT CONTROL UP SWITCH, LIGHT CONTROL DOWN SWITCH)
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [07/2020 - ]
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Light Control Up Switch Light control rheostat up switch OFF or ON OFF: Switch released
ON: Switch pressed- Light Control Down Switch Light control rheostat down switch OFF or ON OFF: Switch released
ON: Switch pressed- Body Electrical > Combination Meter > Data List
Tester Display Light Control Up Switch Light Control Down Switch OK
Light control rheostat up or down switch condition displayed on the Techstream changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2020 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT TRIP SWITCH
- Temporarily replace the trip switch with a new or normally functioning one.
Refer to REMOVAL [07/2020 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [07/2020 - ]
Result:
OK
See step 3
- Temporarily replace the trip switch with a new or normally functioning one.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
- Disconnect the P25 combination meter assembly connector.
- Disconnect the P3 trip switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition P25-25 (TR) - P3-5 (RV) Always Below 1 Ω P25-26 (SW3) - P3-7 (E) Always Below 1 Ω P25-25 (TR) or P3-5 (RV) - Other terminals and body ground Always 10 kΩ or higher P25-26 (SW3) or P3-7 (E) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [07/2020 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR