LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2021 >> LC 500 2D Convertible >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge System - Diagnostic Codes, Symptom Tests & Circuit Tests (Convertible) >> Meter / Gauge System >> Engine Oil Temperature Gauge Malfunction [07/2020 - ] >> Procedure

Engine Oil Temperature Gauge Malfunction [07/2020 - ]: Procedure

  1. CHECK FOR DTC 
    1. Check for DTCs.

      Refer to DTC CHECK / CLEAR [07/2020 - ]

      Body Electrical > Combination Meter > Trouble Codes 

      OK

      No DTCs are output.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO DIAGNOSTIC TROUBLE CODE CHART. Refer to  DIAGNOSTIC TROUBLE CODE CHART [07/2020 - 05/2023]  , or refer to  DIAGNOSTIC TROUBLE CODE CHART [05/2023 - ] 

    Result: 

    OK 

    See step  2

  2. READ VALUE USING TECHSTREAM (COOLANT TEMPERATURE) 
    1. Using the Techstream, read the Data List.

      Refer to DATA LIST / ACTIVE TEST [07/2020 - ]

      Body Electrical > Combination Meter > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Engine Oil Temperature Engine oil temperature Min.: 0°C (32°F), Max.: 255°C (491°F) Engine oil temperature receiver gauge indication: When the indicator is in the center of the gauge: 80 to 105°C(176 to 221°F)When the indicator is in the red zone: 140°C (284°F) or more -

      Body Electrical > Combination Meter > Data List 

      Tester Display
      Engine Oil Temperature

      OK

      The Data List values of the ECUs do not match.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [07/2020 - ] 

    Result: 

    NG 

    See step  3

  3. INSPECT OIL TEMPERATURE SENSOR 
    1. Remove the oil temperature sensor.

      Refer to REMOVAL [07/2020 - ]

    2. Inspect the oil temperature sensor.

      Refer to INSPECTION [07/2020 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE OIL TEMPERATURE SENSOR. Refer to  REMOVAL [07/2020 - ] 

    Result: 

    OK 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - OIL TEMPERATURE SENSOR AND BODY GROUND) 
    1. Disconnect the P25 combination meter assembly connector.
    2. Disconnect the G77 oil temperature sensor connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      P25-24 (GAGE) - G77-1 (OT+) Always Below 1 Ω
      P25-32 (GND) - G77-2 (OT-) Always Below 1 Ω
      P25-31 (ES) - Body ground Always Below 1 Ω
      P25-24 (GAGE) - Other terminals and body ground Always 10 kΩ or higher
      P25-32 (GND) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [07/2020 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR