DTC C1747: Leveling Solenoid Valve Circuit [08/2019 - 08/2021]: Description
The suspension control ECU opens the leveling solenoid valve (No. 2 height control valve assembly) to allow compressed air to flow into the height control cylinder (pneumatic cylinder) and raise the vehicle height.
The No. 2 height control valve assembly consists of a leveling solenoid valve and a gate solenoid valve.
The leveling solenoid valve opens and closes the passage between the height control compressor assembly and the height control cylinder (pneumatic cylinder).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate |
|---|---|---|---|---|
| C1747 | Leveling Solenoid Valve Circuit | Either condition is met:
|
|
Indicated |
HINT:
- Once the suspension control ECU stores DTC C1747 in memory, vehicle height control is suspended until a normal signal is input to the suspension control ECU from the height control valves. However, control is resumed if the engine switch is turned off and then on (IG) again.
- Malfunction in the leveling solenoid valve:
Height control operation is suspended and the height control indicator does not change by operating the height control switch (combination switch assembly).