LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2021 >> GX 460 Luxury >> Repair and Diagnosis >> Accessories & Equipment >> Exterior Lights >> Lighting System (Exterior) (Diagnostic Codes & Circuit Tests) >> Lighting System >> Hazard Warning Switch Circuit [08/2019 - 08/2021] >> Procedure

Hazard Warning Switch Circuit [08/2019 - 08/2021]: Procedure

  1. READ VALUE USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Combination Meter / Data List.
    5. Read the Data List according to the display on the Techstream.
      COMBINATION METER

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard warning signal switch signal/
      OFF or ON
      OFF: Hazard warning signal switch off
      ON: Hazard warning signal switch on
      -

      OK

      Normal condition listed above is displayed.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [08/2019 - ] 

    Result: 

    NG 

    See step  2

  2. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY 
    1. Remove the hazard warning signal switch assembly.

      Refer to REMOVAL [08/2015 - 08/2021]

    2. Inspect the hazard warning signal switch assembly.

      Refer to INSPECTION [08/2015 - 08/2021]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY. Refer to  REMOVAL [08/2015 - 08/2021] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND) 
    1. Disconnect the x1 hazard warning signal switch assembly connector.
    2. Disconnect the G3 combination meter assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      x1-4 (B) - G3-7 (HZSW) Always Below 1 Ω
      x1-4 (B) or G3-7 (HZSW) - Body ground Always 10 kΩ or higher
      x1-1 (E) - Body ground Always Below 1 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [08/2019 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR