Hazard Warning Switch Circuit [08/2019 - 08/2021]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch signal/
OFF or ONOFF: Hazard warning signal switch off
ON: Hazard warning signal switch on- OK
Normal condition listed above is displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [08/2019 - ]
Result:
NG
See step 2
- INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
- Remove the hazard warning signal switch assembly.
Refer to REMOVAL [08/2015 - 08/2021]
- Inspect the hazard warning signal switch assembly.
Refer to INSPECTION [08/2015 - 08/2021]
Result
Proceed to OK NG
Result:
NG
REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY. Refer to REMOVAL [08/2015 - 08/2021]
Result:
OK
See step 3
- Remove the hazard warning signal switch assembly.
- CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the x1 hazard warning signal switch assembly connector.
- Disconnect the G3 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition x1-4 (B) - G3-7 (HZSW) Always Below 1 Ω x1-4 (B) or G3-7 (HZSW) - Body ground Always 10 kΩ or higher x1-1 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [08/2019 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR