Inspection [10/2018 - 07/2022]: Procedure
- INSPECT CLOCK ASSEMBLY
- Check illumination.
- Apply auxiliary battery voltage to the clock assembly and check that it illuminates.
*a Component without harness connected
(Clock Assembly)OK
Tester Connection Specified Condition Auxiliary battery positive (+) → 3 (ILL+)
Auxiliary battery positive (-) → 8 (ILL-)Illuminates If the result is not as specified, replace the clock assembly.
- Apply auxiliary battery voltage to the clock assembly and check that it illuminates.
- Check illumination.