Section 62 (Motor Generator Control System (Diagnostic Codes) (1 Of 3))
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
- Motor Generator Control System
- DTC P0335-00: Crankshaft Position Sensor "A"; DTC P033531: Crankshaft Position Sensor "A" No Signal [10/2018 - ]
- DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P034031: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [10/2018 - ]
- DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [10/2018 - ]
- DTC P062F-46: Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure [10/2018 - ]
- DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ]
- DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A0015: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [10/2018 - ]
- DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [10/2018 - ]
- DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A0814: DC/DC Converter Status Circuit Short to Ground or Open [10/2018 - ]
- DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A1114: DC/DC Converter Enable Circuit Short to Ground or Open [10/2018 - ]
- DTC P0A1B-1F: Generator Control Module Circuit Intermittent [10/2018 - ]
- DTC P0A1C-49: Drive Motor "B" Control Module Internal Electronic Failure [10/2018 - ]
- DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F1F: Drive Motor "A" Position Sensor Circuit Intermittent [10/2018 - ]
- DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [10/2018 - ]
- DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B1F: Generator Position Sensor Circuit Intermittent [10/2018 - ]
- DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B22: Generator Position Sensor Signal Amplitude > Maximum [10/2018 - ]
- DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ]
- DTC P0A78-72: Drive Motor "A" Inverter Actuator Stuck Open [10/2018 - ]
- DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [10/2018 - ]
- DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D19: Drive Motor "A" Inverter Circuit Current Above Threshold [10/2018 - ]
- DTC P0A7A-72: Generator Inverter Actuator Stuck Open [10/2018 - ]
- DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [10/2018 - ]
- DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F19: Generator Inverter Circuit Current Above Threshold [10/2018 - ]