LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2020 >> UX 200 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 60 (Air Conditioning System - Diagnostic Codes (1 Of 2) (Hybrid)) >> AIR CONDITIONING SYSTEM (for HV Model) >> DTC B1476: A/C Inverter Load System [10/2018 - 07/2022] >> Procedure

DTC B1476: A/C Inverter Load System [10/2018 - 07/2022]: Procedure

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
  1. PERFORM ACTIVE TEST USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Powertrain / Engine / Active Test.
    5. Perform the Active Test according to the display on the Techstream.

      Powertrain > Engine > Active Test 

      Tester Display Measurement Item Control Range Diagnostic Note
      Control the Engine Cooling Fan Duty Ratio Control the cooling fan 0 to 100% Perform this test when vehicle is stopped.

      Powertrain > Engine > Active Test 

      Tester Display
      Control the Engine Cooling Fan Duty Ratio

      OK

      Cooling fan operates smoothly.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO COOLING FAN SYSTEM. Refer to  ON-VEHICLE INSPECTION [10/2018 - ] 

    Result: 

    OK 

    See step  2

  2. CHECK REFRIGERANT PRESSURE 
    1. Install a manifold gauge set.

      Refer to ON-VEHICLE INSPECTION [10/2018 - 07/2022]

    2. Turn the power switch on (READY).
    3. Read the manifold gauge pressure when the following conditions are met.
      • Prepare the vehicle according to the table below.
        Item Condition
        Vehicle doors Fully open
        Temperature setting MAX COLD
        Blower speed HI
        A/C switch On
        Recirculation/fresh switch RECIRCULATION
        Interior temperature 25 to 35°C (77 to 95°F)

      Standard Pressure

      Low pressure side 

      150 to 250 kPa (1.5 to 2.5 kgf/cm2 , 22 to 36 psi)

      High pressure side 

      1370 to 1570 kPa (14 to 16 kgf/cm2 , 199 to 228 psi)

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE COMPRESSOR WITH MOTOR ASSEMBLY. Refer to  REMOVAL [10/2018 - 07/2022] 

    Result: 

    NG 

    CHARGE REFRIGERANT. Refer to  REPLACEMENT [10/2018 - 07/2022]