DTC B1411: Room Temperature Sensor Circuit [10/2018 - ]: Procedure

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
  1. READ VALUE USING TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.
    5. Read the Data List according to the display on the Techstream.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
      Max.: 57.25°C (135.05°F)
      Actual cabin temperature displayed Cooler (room temp. sensor) thermistor circuit malfunction
      • When open circuit: -6.50°C (20.30°F)
      • When short circuit: 57.25°C (135.05°F)

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Room Temperature Sensor

      OK

      The display is as specified in the normal condition column.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [10/2018 - 07/2022]  , or refer to  REMOVAL [07/2022 - ] 

    Result: 

    NG 

    See step  2

  2. INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR 
    1. Remove the cooler (room temp. sensor) thermistor.

      Refer to REMOVAL [10/2018 - ]

    2. Inspect the cooler (room temp. sensor) thermistor.

      Refer to INSPECTION [10/2018 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE COOLER (ROOM TEMP. SENSOR) THERMISTOR. Refer to  REMOVAL [10/2018 - ] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) 
    1. Disconnect the F50 air conditioning amplifier assembly connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      F67-1 (+) - F50-14 (TR) Always Below 1 Ω
      F67-2 (-) - F50-1 (SG-1) Always Below 1 Ω
      F67-1 (+) or F50-14 (TR) - Other terminals and body ground Always 10 kΩ or higher
      F67-2 (-) or F50-1 (SG-1) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [10/2018 - 07/2022]  , or refer to  REMOVAL [07/2022 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR