DTC P0ABF-2A: Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range [10/2018 - ]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check and record any HV system DTCs and freeze frame data.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to "Only DTC P0ABF2A is output" or "DTC P0ABF2A and DTCs other than those in the following table are output". A DTC P0ABF2A and any of the DTCs in the following table are output at the same time. B Relevant DTC P0A9563 High Voltage Fuse Accumulated Load History P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open P0AFC00 Hybrid/EV Battery Sensor Module P0AFC96 Hybrid/EV Battery Sensor Module Component Internal Failure P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open P308A12 Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery P0B3B14, P0B4014, P0B4514, P0B4A14, P0B4F14, P0B5414, P0B5914, P0B5E14, P0B6314, P0B6814, P0B6D14 Hybrid/EV Battery Voltage Sensor "A - K" Circuit Short to Ground or Open - Turn the power switch off.
Result:
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [10/2018 - ]
Result:
A
See step 2
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).NOTE:
Do not turn the power switch on (READY).
- Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Block 1 to 10 Voltage.NOTE:
Select "Hybrid Battery Block 1 to 10 Voltage" only. (Do not select any other Data List items.)
Powertrain > Hybrid Control > Data List
Tester Display Hybrid Battery Block 1 Voltage Hybrid Battery Block 2 Voltage Hybrid Battery Block 3 Voltage Hybrid Battery Block 4 Voltage Hybrid Battery Block 5 Voltage Hybrid Battery Block 6 Voltage Hybrid Battery Block 7 Voltage Hybrid Battery Block 8 Voltage Hybrid Battery Block 9 Voltage Hybrid Battery Block 10 Voltage - Check the voltage of each "Battery Block Vol" of "Hybrid Battery Block 1 to 10 Voltage" in the Data List with the power switch on (IG).
Specified Condition
Any "Battery Block Vol" changes by 0.3 V or more, 60 seconds after the power switch is turned on (IG). (The difference between the maximum and minimum voltage is 0.3 V or more.)
Result
Result Proceed to The change in voltage of any "Hybrid Battery Block Voltage" is 0.3 V or more. A Other than above B - Turn the power switch off.
Result:
A
REPLACE BATTERY VOLTAGE SENSOR. Refer to REMOVAL [10/2018 - 07/2022] Refer to REMOVAL [07/2022 - ]
Result:
B
REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [10/2018 - 07/2022] Refer to REMOVAL [07/2022 - ]