Inspection [10/2018 - ]: Procedure
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
- INSPECT CANISTER (CHARCOAL CANISTER ASSEMBLY)
- Visually check the canister (charcoal canister assembly).
- Visually check the canister (charcoal canister assembly) for cracks or damage.
If cracks or damage are found, replace the canister (charcoal canister assembly).
- Visually check the canister (charcoal canister assembly) for cracks or damage.
- Check the canister (charcoal canister assembly) operation.
- With the purge line port closed, blow 0.5 kPa (0.005 kgf/cm2
, 0.1 psi) of air into the vent line port, and check that air flows from the air line port.
If the result is not as specified, replace the canister (charcoal canister assembly).
*a Vent Line Port *b Air Line Port *c Purge Line Port *d Air - With the vent line port closed, blow 0.5 kPa (0.005 kgf/cm2
, 0.1 psi) of air into the air line port, and check that air flows from the purge line port.
If the result is not as specified, replace the canister (charcoal canister assembly).
*a Vent Line Port *b Air Line Port *c Purge Line Port *d Air
- With the purge line port closed, blow 0.5 kPa (0.005 kgf/cm2
, 0.1 psi) of air into the vent line port, and check that air flows from the air line port.
- Check for air leaks.
- Connect a pressure gauge to the vent line port.
*a Pressure Gauge *b Vent Line Port *c Air Line Port *d Purge Line Port *e Charcoal Canister Leak Detection Pump Sub-assembly Connector - With the purge line port, air line port and charcoal canister leak detection pump sub-assembly connector closed, apply 20 kPa (150 mmHg, 5.91 in. Hg) of pressurized air into the vent line port, then confirm that pressure is maintained for 1 minute.
If the result is not as specified, replace the canister (charcoal canister assembly).
- Connect a pressure gauge to the vent line port.
- Check the charcoal canister leak detection pump sub-assembly.
- Connect a positive (+) auxiliary battery lead to terminal 5 and a negative (-) auxiliary battery lead to terminal 1.
- Check that a clicking sound is heard from the charcoal canister leak detection pump sub-assembly.
If the result is not as specified, replace the charcoal canister leak detection pump sub-assembly.
- Connect a positive (+) auxiliary battery lead to terminal 5 and a negative (-) auxiliary battery lead to terminal 1.
- Visually check the canister (charcoal canister assembly).