LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2020 >> UX 200 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 14 (Hybrid Control System (Diagnostic Codes) (1 Of 5)) >> Hybrid Control System >> DTC P0A81-96: Hybrid/EV Battery Cooling Fan 1 Component Internal Failure; DTC P0A8198: Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature [10/2018 - ] >> Description

DTC P0A81-96: Hybrid/EV Battery Cooling Fan 1 Component Internal Failure; DTC P0A8198: Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature [10/2018 - ]: Description

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.

Refer to the description for DTC P0A8111.

Refer to DESCRIPTION 

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A8196 Hybrid/EV Battery Cooling Fan 1 Component Internal Failure The battery cooling blower assembly is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.*
*: This DTC is not stored when "Hybrid Battery Cooling Fan 1 Frequency" is excessively low or high.
(2 trip detection logic)
  • Battery cooling blower assembly
  • Battery voltage sensor
  • Hybrid vehicle control ECU
  • No. 1 HV battery intake filter
  • No. 1 Hybrid battery intake duct
  • Wire harness or connector
Comes on Master Warning:
Comes on
P0A8198 Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature The HV battery temperature is high and the battery cooling blower assembly is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.*
*: This DTC is not stored when "Hybrid Battery Cooling Fan 1 Frequency" is excessively low or high.
(1 trip detection logic)
  • Battery cooling blower assembly
  • Battery voltage sensor
  • Hybrid vehicle control ECU
  • No. 1 HV battery intake filter
  • No. 1 Hybrid battery intake duct
  • No. 1 Hybrid battery intake duct LH
  • Wire harness or connector
Comes on Master Warning:
Comes on
RELATED DATA LIST

DTC No. Data List
P0A8196
  • Hybrid Battery Cooling Fan 1 Drive Request
  • Hybrid Battery Cooling Fan 1 Drive Status
  • Hybrid Battery Cooling Fan 1 Frequency
P0A8198

The following items can be helpful when performing repairs:

Data List 

HINT: 

"Hybrid Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly rotation speed.