Weak Blower Output [10/2018 - ]: Procedure
- CHECK AIR CONDITIONING SYSTEM
- Operate the blower switch with the following conditions met and check that the airflow volume changes.
Blower Speed Condition LO → HI - Temperature setting: MAX COLD
- Air outlet mode: FACE
- A/C switch: Off
OK
Airflow volume increases.
Result
Proceed to OK NG
Result:
NG
GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit). Refer to Blower Motor Circuit [10/2018 - ]
Result:
OK
See step 2
- Operate the blower switch with the following conditions met and check that the airflow volume changes.
- CHECK ECO MODE SETTING
Result:
OK
See step 4
Result:
NG
See step 3
- CHECK ECO MODE CONTROL OPERATION
- Operate the ECO switch (satellite switch set) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.
HINT:
- When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
Control Outline Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced. Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode. - In some situations, ECO mode control may not operate even though it is enabled.
Result
Result Proceed to ECO mode indicator turns off and blower speed reduction is canceled A ECO mode indicator turns off, but the blower speed reduction is not canceled B ECO mode indicator does not turn off - When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
Result:
B
GO TO ECO Switch Circuit. Refer to ECO Switch Circuit [10/2018 - 07/2022] , or refer to ECO Switch Circuit [07/2022 - ]
Result:
A
See step 4
- Operate the ECO switch (satellite switch set) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.
- CHECK CLEAN AIR FILTER
- Visually check the clean air filter.
Refer to REMOVAL [10/2018 - ]
OK
The clean air filter is not dirty or clogged.
Result
Proceed to OK NG
Result:
NG
REPLACE CLEAN AIR FILTER. Refer to REMOVAL [10/2018 - ]
Result:
OK
See step 5
- Visually check the clean air filter.
- CHECK NO. 1 COOLER THERMISTOR
- Check the installation condition of the No. 1 cooler thermistor.
OK
The No. 1 cooler thermistor is installed correctly.
Result
Proceed to OK NG
Result:
NG
INSTALL NO. 1 COOLER THERMISTOR. Refer to INSTALLATION [10/2018 - 10/2020] , or refer to INSTALLATION [10/2020 - 07/2022] , or refer to INSTALLATION [07/2022 - ]
Result:
OK
See step 6
- Check the installation condition of the No. 1 cooler thermistor.
- CHECK ASPIRATOR PIPE
- Check the installation condition of the aspirator pipe.
OK
The aspirator pipe is installed correctly.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY. Refer to REMOVAL [10/2018 - 07/2022] , or refer to REMOVAL [07/2022 - ]
Result:
NG
INSTALL ASPIRATOR PIPE. Refer to REASSEMBLY [10/2018 - 10/2020] , or refer to REASSEMBLY [10/2020 - 07/2022] , or refer to REASSEMBLY [07/2022 - ]
- Check the installation condition of the aspirator pipe.