LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2020 >> UX 200 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 12 (Air Conditioning System - Diagnostic Codes (2 Of 2) & Symptom Tests) (Hybrid)) >> AIR CONDITIONING SYSTEM (for HV Model) >> Weak Blower Output [10/2018 - ] >> Procedure

Weak Blower Output [10/2018 - ]: Procedure

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK AIR CONDITIONING SYSTEM 
    1. Operate the blower switch with the following conditions met and check that the airflow volume changes.
      Blower Speed Condition
      LO → HI
      • Temperature setting: MAX COLD
      • Air outlet mode: FACE
      • A/C switch: Off

      OK

      Airflow volume increases.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit). Refer to  Blower Motor Circuit [10/2018 - ]  

    Result: 

    OK 

    See step  2

  2. CHECK ECO MODE SETTING 
    1. Check if the ECO mode indicator is off.

      OK

      The ECO mode indicator is off.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    See step  4

    Result: 

    NG 

    See step  3

  3. CHECK ECO MODE CONTROL OPERATION 
    1. Operate the ECO switch (satellite switch set) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.

      HINT: 

      • When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
        Control Outline
        Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced.
        Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode.
      • In some situations, ECO mode control may not operate even though it is enabled.

      Result

      Result Proceed to
      ECO mode indicator turns off and blower speed reduction is canceled A
      ECO mode indicator turns off, but the blower speed reduction is not canceled B
      ECO mode indicator does not turn off

    Result: 

    GO TO ECO Switch Circuit. Refer to  ECO Switch Circuit [10/2018 - 07/2022]  , or refer to  ECO Switch Circuit [07/2022 - ]  

    Result: 

    See step  4

  4. CHECK CLEAN AIR FILTER 
    1. Visually check the clean air filter.

      Refer to REMOVAL [10/2018 - ]

      OK

      The clean air filter is not dirty or clogged.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE CLEAN AIR FILTER. Refer to  REMOVAL [10/2018 - ] 

    Result: 

    OK 

    See step  5

  5. CHECK NO. 1 COOLER THERMISTOR 
    1. Check the installation condition of the No. 1 cooler thermistor.

      OK

      The No. 1 cooler thermistor is installed correctly.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    INSTALL NO. 1 COOLER THERMISTOR. Refer to  INSTALLATION [10/2018 - 10/2020]  , or refer to  INSTALLATION [10/2020 - 07/2022]  , or refer to  INSTALLATION [07/2022 - ] 

    Result: 

    OK 

    See step  6

  6. CHECK ASPIRATOR PIPE 
    1. Check the installation condition of the aspirator pipe.

      OK

      The aspirator pipe is installed correctly.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY. Refer to  REMOVAL [10/2018 - 07/2022]  , or refer to  REMOVAL [07/2022 - ] 

    Result: 

    NG 

    INSTALL ASPIRATOR PIPE. Refer to  REASSEMBLY [10/2018 - 10/2020]  , or refer to  REASSEMBLY [10/2020 - 07/2022]  , or refer to  REASSEMBLY [07/2022 - ]