Cooling is Poor [07/2022 - ]: Procedure
- CHECK FOR DTC
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Trouble Codes.
- Check for DTCs.
Body Electrical > Main Body > Trouble Codes
Result
Result Proceed to B1244 is not output A B1244 is output B
Result:
B
GO TO DTC B1244. Refer to DTC B1244: Light Sensor Circuit [07/2022 - ]
Result:
A
See step 2
- CHECK ECO MODE SETTING
Result:
NG
See step 4
Result:
OK
See step 3
- CHECK ECO MODE CONTROL OPERATION
- Operate the ECO switch (satellite switch set) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.
HINT:
- When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
Control Outline Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced. Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode. - In some situations, ECO mode control may not operate even though it is enabled.
Result
Result Proceed to ECO mode indicator turns off and blower speed reduction is canceled A ECO mode indicator turns off, but the blower speed reduction is not canceled B ECO mode indicator does not turn off - When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
Result:
B
GO TO ECO Switch Circuit. Refer to ECO Switch Circuit [07/2022 - ]
Result:
A
See step 4
- Operate the ECO switch (satellite switch set) and check that the ECO mode indicator turns off and the blower speed reduction is canceled.
- PERFORM REFRIGERANT SHORTAGE CHECK
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check - Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.MEASUREMENT CONDITION:
Item Condition A/C switch On Ambient temperature* 0 to 49°C (32 to 120°F) Blower speed HI *: If the ambient temperature is not within the range shown, do not perform this check.
Result
Result Amount of Refrigerant Refrigerant correct Correct Refrigerant shortage Insufficient OK
"Refrigerant correct" is displayed on the Techstream.
Result
Proceed to OK NG
Result:
NG
REPAIR REFRIGERANT LEAK
for HFC-134a(R134a): Refer to REPLACEMENT [07/2022 - ]
for HFO-1234yf(R1234yf): Refer to REPLACEMENT [07/2022 - ]
Result:
OK
See step 5
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383Operates between 165 and 257 pulses Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383Operates between 255 and 347 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(P) OK
Each damper servo motor operates.
Result
Proceed to OK NG
Result:
OK
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET
for HFC-134a(R134a): Refer to ON-VEHICLE INSPECTION [07/2022 - ]
for HFO-1234yf(R1234yf): Refer to ON-VEHICLE INSPECTION [07/2022 - ]
Result:
NG
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR. Refer to DIAGNOSTIC TROUBLE CODE CHART [07/2022 - ]