LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2020 >> UX 200 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 11 (Hybrid Battery Control System (Service Information) (1 Of 2)) >> Motor Generator Control Computer >> Removal [10/2018 - 07/2022] >> Procedure

Removal [10/2018 - 07/2022]: Procedure

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
  1. REMOVE INVERTER WITH CONVERTER ASSEMBLY 

    Refer to REMOVAL [10/2018 - 07/2022] 

  2. REMOVE TRANSMISSION CONTROL CABLE SUPPORT 

    See step  27

  3. REMOVE WIRE HARNESS CLAMP BRACKET 

    See step  28

  4. VERIFY THAT VOLTAGE OF INVERTER WITH CONVERTER IS 0 V 
    WARNING:

    Wear insulating gloves.

    NOTE:

    Do not allow any foreign matter or water to enter the inverter with converter assembly.

    1. Remove the protective tape from the HV floor under wire opening.
      GTY707525Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Tape
    2. Using a voltmeter, measure the voltage between the high voltage cable connector terminals.
      GTY699746Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Voltage Measurement Position

      Standard voltage

      0V

      HINT: 

      • Use measuring range of DC 750 V or more on the voltmeter.
      • If it is confirmed that high-voltage is not being applied to the inverter with converter assembly, the following procedures can be performed without using insulated tools or gloves.
    3. Apply protective tape to the area that was exposed.
      NOTE:

      Use non-residue type tape.

  5. CLEAN INVERTER WITH CONVERTER ASSEMBLY 
    1. Using a piece of cloth, clean the outside of the inverter with converter assembly and around the bolts.
      NOTE:

      To prevent foreign matter from entering the inverter with converter assembly, make sure that the protective tape is not partially removed.

  6. HOW TO PREVENT STATIC ELECTRICITY 
    • SST: 09890-47010 
    NOTE:
    • Static electricity should be eliminated when removing/installing the inverter with converter assembly.
    • Do not touch the electronic components of a circuit board.
    • Keep clothes away from electronic components.
    • Place the inverter with converter assembly and any removed electronic components on SST (antistatic mat).
    1. Wear an antistatic wrist strap.
      GTY477357Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Connect the ground clip of the antistatic mat securely to a ground point provided in the workshop or on a workbench (anchor bolt).

      HINT: 

      If the ground clip cable is too short, use an extension cable.

    3. Connect the ground clip of the antistatic wrist strap securely to the specified point of the antistatic mat.
    4. When handling internal components of the inverter with converter assembly, use only antistatic gloves or bare hands to prevent damage from static electricity or the entry of foreign matter.
  7. REMOVE INVERTER UPPER COVER 
    1. Remove the 10 bolts.
      GTY1003981Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Using a screwdriver with its tip wrapped with protective tape, remove the inverter upper cover from the inverter with converter assembly.
      GTY1003473Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Protective Tape - -
    3. Using a screwdriver with its tip wrapped with protective tape, remove the inverter upper cover from the inverter with converter assembly.
      NOTE:
      • Do not damage the sealing surfaces of the inverter with converter assembly.
        GTY1004066Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        *a OK
        *b NG
      • Do not touch or allow grease or oil to contact the sealing surfaces of the inverter with converter assembly.
      • Be careful not to damage the sealing surfaces of the inverter with converter assembly.
      • To prevent internal components of the inverter with converter assembly from being damaged, do not insert the screwdriver excessively.

      HINT: 

      I f the upper inverter panel is difficult to remove, place a screwdriver in a gap under the upper inverter cover and remove.

      GTY1003969Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  8. REMOVE SEAL PACKING FROM INVERTER WITH CONVERTER ASSEMBLY 
    NOTE:
    • Do not allow any removed seal packing to enter the inverter with converter assembly.
    • Do not touch the circuit board.
    • Do not allow any moisture to come into contact.
    1. Using a finger, remove any seal packing that has seeped into the inverter with converter assembly.

      HINT: 

      Make sure to remove any seal packing which has seeped toward the inside of inverter with converter assembly before installing the seal packing removal cover, otherwise the seal packing may be pushed into the inverter with converter assembly.

    2. GTY1004255Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Break off the seal packing removal cover and scraper at each break off line.

    3. Set the seal packing removal cover on the inverter with converter assembly and secure it by lightly pressing it at the 2 areas shown in the illustration.
      GTY1003972Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a A-A Cross Section *b B-B Cross Section
      Push - -
      NOTE:

      Make sure that the seal packing removal cover is in secure contact with the inside surface of the inverter with converter assembly without any gaps.

    4. Place the inverter with converter assembly on its side on an antistatic mat as shown in the illustration.
      NOTE:
      • Make sure that the MG connector opening in the inverter with converter assembly is facing upward.
      • Make sure that the inverter with converter assembly is oriented correctly, otherwise seal packing may enter the inverter with converter assembly.
      GTY1003351Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a MG Connector Opening
    5. Using a scraper, remove any remaining seal packing from the inverter with converter assembly.
      NOTE:
      • It is not necessary to remove small amounts of seal packing which are not easily scraped off.
        GTY686879Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        *a Correct *b Incorrect
        *c Width of Sealing Surface *d Difficult to Remove Seal Packing
        *e Peeled Off Seal Packing *f Seal Packing Remaining on Full Width of Sealing Surface
      • Make sure to use the scraper supplied with the seal packing removal cover.
        GTY731991Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT: 

      Use the small end of the scraper to remove seal packing from small areas such as bolt holes.

    6. Using a clean piece of cloth, clean the sealing surfaces of the inverter with converter assembly.
      NOTE:
      • Do not use compressed air or a vacuum cleaner to clean the sealing surfaces of the inverter with converter assembly.
      • Do not use non-residue solvent to clean the sealing surfaces of the inverter with converter assembly.
    7. Remove the seal packing removal cover.
      GTY1003967Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE:

      Make sure that the inverter with converter assembly is oriented correctly, otherwise seal packing may enter the inverter with converter assembly when removing the seal packing removal cover.

    8. Check for and remove any foreign matter which has entered the inverter with converter assembly.
    9. Set the inverter with converter assembly upright.
    10. Clean the seal packing removal cover.

      HINT: 

      As the seal packing removal cover will be reused, it is necessary to clean it to prevent foreign matter from entering the inverter with converter assembly and prevent damage.

  9. REMOVE MOTOR GENERATOR CONTROL ECU KIT 
    WARNING:

    To prevent foreign matter from entering the inverter with converter assembly, once the seal packing removal cover has been removed, work cannot be suspended until the motor generator control ECU kit is reinstalled.

    NOTE:
    • Do not touch the circuit board.
    • Do not allow any foreign matter or water to enter the inverter with converter assembly.
    1. Install the seal packing removal cover to the inverter with converter assembly.

      HINT: 

      The seal packing removal cover is installed to help prevent the motor generator control computer kit from being damaged if a part or tool is dropped on it.

    2. Install the 2 guide pins by hand at the positions shown in the illustration.
      NOTE:

      Make sure that the guide pins are tightened securely.

      GTY1003968Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. GTY1003959Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Remove the seal packing removal cover.

    4. Check that the 4 screws of the circuit board replacement jig are unlocked, and then while holding the circuit board replacement jig by the ribs, align it with the guide pins and set it on the inverter with converter assembly.

      HINT: 

      Make sure that circuit board replacement jig is perfectly level with the sealing surface.

      GTY1003057Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      Unlock
      Rib
    5. Secure the circuit board replacement jig with the 2 bolts supplied with the circuit board replacement jig.
      GTY1003606Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Locked
      *b Knob
      Bolt
      Lock
      NOTE:

      Tighten the bolt by hand until the head contacts the jig.

    6. Lock the 4 screws as shown in the illustration to secure the circuit board replacement jig to the circuit board.
      NOTE:

      When locking the screws of the circuit board replacement jig, do not apply excessive force to the screws, otherwise the circuit board replacement jig may be damaged.

      HINT: 

      Make sure that the screws of the circuit board replacement jig are securely locked.

    7. Turn the 4 knobs of the circuit board replacement jig clockwise and secure the 4 screws of the circuit board replacement jig.
    8. Using SST, release the lock of each vibration dampening connector and raise the 28 vibration dampening connectors until they reach the stopper of the circuit board replacement jig.
      • SST: 09905-00040 
      NOTE:

      When disconnecting the vibration dampening connectors, release the lock of each connector with SST and then carefully lift the connector the specified amount.

      HINT: 

      • To prevent the vibration dampening connectors from being pulled up excessively, use both hands to raise them slowly as shown in the illustration.
      • The position of the lock will vary depending on the position of the vibration dampening connector. Refer to the arrows on the circuit board replacement jig.
      GTY708141Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      GTY1002908Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Connected Vibration Dampening Connector
      *b Disconnected Vibration Dampening Connector
      *c Stopper of The Circuit Board Replacement Jig
    9. Using the screwdriver supplied with the circuit board replacement jig, remove the 3 bolts (A).

      HINT: 

      If the bolts are difficult to remove from the circuit board replacement jig, use a magnet hand.

      GTY1003493Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      Bolt (A)
      Bolt (B)
    10. Using the screwdriver supplied with the circuit board replacement jig, remove the 13 bolts (B).

      HINT: 

      If the bolts are difficult to remove from the circuit board replacement jig, use a magnet hand.

    11. Remove the 2 inverter upper cover installation bolts.
    12. While holding the circuit board replacement jig by the ribs, evenly lift the circuit board replacement jig and circuit board straight up and remove it.
      GTY1003448Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      Rib
    13. Place the circuit board replacement jig upside down on a clean workbench.
      GTY1004243Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    14. Check that the terminals of the inverter with converter assembly are not bent or damaged and that it is free of foreign matter.
      GTY704951Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Correct *b Incorrect
      *c Terminal - -
      NOTE:
      • Do not touch the terminals.
      • If any of the terminals are bent, replace the inverter with converter assembly with a new one. Do not attempt to repair the terminals.
    15. Turn the 4 knobs of the circuit board replacement jig counterclockwise and release the 4 screws of the circuit board replacement jig.
      GTY1003386Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Hold here *b Do not hold here
      *c Circuit Board *d Circuit Board Replacement Jig
      *e Knob - -
      Unlock - -
    16. Unlock the 4 circuit board replacement jig screws, and then while holding the sides of the circuit board or the top and bottom of the circuit board at the areas shown in the illustration, lift the circuit board to remove it from the circuit board replacement jig.
      NOTE: