Switch Lights of Remote Touch do not Illuminate [10/2015 - 08/2019]: Procedure
- CHECK SYMPTOMS
- Perform the following procedure and check the switch illumination again.
*a Switch Illumination - If the vehicle is in a bright area, move it to a dark area.
HINT:
When the vehicle is in a bright area, the switch illumination may not turn on due to the automatic dimmer function.
- Set the rheostat to maximum brightness.
HINT:
If the brightness of the rheostat is set to low, switch illumination may not be recognized even when the switch illumination turns on.
- If the light control switch is in the AUTO position, turn the switch to the tail or head position.
HINT:
If the light control switch is in the AUTO position, the switch illumination will not turn on unless the surrounding area is dark.
OK
Switch illumination turns on.
Result
Proceed to OK NG - If the vehicle is in a bright area, move it to a dark area.
Result:
OK
END
Result:
NG
See step 2
- Perform the following procedure and check the switch illumination again.
- REMOTE TOUCH SELF CHECK (SWITCH ILLUMINATION CHECK)
- Activate self check mode.
Refer to OPERATION CHECK [10/2015 - 12/2017] , or refer to OPERATION CHECK [12/2017 - 08/2019]
- Check switch illumination.
*a Switch Illumination *b Switch Knob - Move the remote touch switch knob from the lower left to the upper right to check that the brightness of the switch illumination changes.
OK
The switch illumination brightness changes according to the remote touch switch knob operation.
Result
Proceed to OK NG - Move the remote touch switch knob from the lower left to the upper right to check that the brightness of the switch illumination changes.
Result:
NG
See step 6
Result:
OK
See step 3
- Activate self check mode.
- CHECK HARNESS AND CONNECTOR (ILLUMINATION SIGNAL)
- Disconnect the g1 remote touch (remote operation board) connector.
- Measure the voltage according to the value (s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition g1-9 (ILL+) - Body ground Power switch off
Light control switch in tail or head position11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (REMOTE TOUCH (REMOTE OPERATION BOARD) - COMBINATION METER ASSEMBLY)
- Disconnect the g1 remote touch (remote operation board) connector.
- Disconnect the J10 combination meter assembly connector.
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition g1-16 (ILL-) - J10-39 (ILL-) Always Below 1 Ω g1-16 (ILL-) or J10-39 (ILL-) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- REPLACE REMOTE OPERATION BOARD
- Replace the remote operation board with a new or known good one.
Refer to DISASSEMBLY [10/2015 - 12/2017] , or refer to DISASSEMBLY [12/2017 - 08/2019]
- Check if the switch illumination turns on.
OK
The switch illumination turns on when the light control switch is in the tail or head position.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2015 - ]
- Replace the remote operation board with a new or known good one.
- REPLACE REMOTE OPERATION SWITCH
- Replace the remote operation switch with a new or known good one.
Refer to DISASSEMBLY [10/2015 - 12/2017] , or refer to DISASSEMBLY [12/2017 - 08/2019]
- Check if the switch illumination turns on.
OK
The switch illumination turns on when the light control switch is in the tail or head position.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
REPLACE REMOTE OPERATION BOARD. Refer to DISASSEMBLY [10/2015 - 12/2017] , or refer to DISASSEMBLY [12/2017 - 08/2019]
- Replace the remote operation switch with a new or known good one.