Switch Lights of Remote Touch do not Illuminate [12/2017 - 08/2019]: Procedure
- CHECK HARNESS AND CONNECTOR (ILLUMINATION SIGNAL)
- Disconnect the J59 remote operation board connector.
- Measure the voltage according to the value (s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition J59-1 (ILL+) - Body ground Power switch off
Light control switch in tail or head position11 to 14 V Result
Result Proceed to OK A NG B
Result:
B
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
A
See step 2
- CHECK HARNESS AND CONNECTOR (REMOTE OPERATION BOARD - COMBINATION METER ASSEMBLY)
- Disconnect the J59 remote operation board connector.
- Disconnect the J10 combination meter assembly connector.
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition J59-8 (ILL-) - J10-39 (ILL-) Always Below 1 Ω J59-8 (ILL-) or J10-39 (ILL-) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- REPLACE REMOTE OPERATION BOARD
- Replace the remote operation board with a new or known good one.
Refer to REMOVAL [10/2015 - 08/2019]
- Check if the switch illumination turns on.
OK
The switch illumination turns on when the light control switch is in the tail or head position.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2015 - ]
- Replace the remote operation board with a new or known good one.