Meter Illumination does not Dim at Night [09/2015 - ]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check for DTCs. Refer to DTC CHECK / CLEAR [09/2015 - ]
).RESULT
Result Proceed to CAN communication system DTC is not output A CAN communication system DTC is output B
Result:
B
GO TO CAN COMMUNICATION SYSTEM
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2015 - 08/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2020 - ] )
Result:
A
See step 2
- Check for DTCs. Refer to DTC CHECK / CLEAR [09/2015 - ]
).
- READ VALUE USING TECHSTREAM (LIGHT CONTROL RHEOSTAT)
- Operate the Techstream according to the display and select the Data List. Refer to DATA LIST / ACTIVE TEST [09/2015 - 08/2017]
, or refer to DATA LIST / ACTIVE TEST [08/2017 - ]
).COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW TAIL cancel switch condition/ON or OFF ON: TAIL cancel switch on
OFF: TAIL cancel switch off- Rheostat value Light control rheostat switch input/Min.: 0, Max.: 100 Light control rheostat switch is fully turned left (0) → fully turned right (100) Unit: % OK
Light brightness can be changed within specified range by manual operation.
Result:
NG
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
OK
See step 3
- Operate the Techstream according to the display and select the Data List. Refer to DATA LIST / ACTIVE TEST [09/2015 - 08/2017]
, or refer to DATA LIST / ACTIVE TEST [08/2017 - ]
).
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat. Refer to REMOVAL [09/2015 - ] ).
- Inspect the light control rheostat.
- Light Control Rheostat: Refer to INSPECTION [09/2015 - ]
- ODO/TRIP Switch: Refer to INSPECTION [09/2015 - ]
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT
Refer to REMOVAL [09/2015 - ] )
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the E120 combination meter assembly connector.
- Disconnect the E9 light control rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E120-30 (ILL+) - E9-5 (T) Always Below 1 Ω E120-31 (TR) - E9-7 (TR) Always Below 1 Ω E120-19 (E2) - E9-1 (E) Always Below 1 Ω E120-32 (TC) - E9-6 (TC) Always Below 1 Ω E120-8 (RSET) - E9-4 (A/B) Always Below 1 Ω E120-30 (ILL+) or E9-5 (T) - Body ground Always 10 kΩ or higher E120-31 (TR) or E9-7 (TR) - Body ground Always 10 kΩ or higher E120-19 (E2) or E9-1 (E) - Body ground Always 10 kΩ or higher E120-32 (TC) or E9-6 (TC) - Body ground Always 10 kΩ or higher E120-8 (RSET) or E9-4 (A/B) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [09/2015 - ] )
Result:
NG