Caution / Notice / Hint
NOTE:
- To measure the resistance of the CAN bus, turn the power switch off, wait at least 1 minutes without operating any keys or switches or opening or closing the doors, disconnect the auxiliary battery, wait at least 1 minutes again, and then measure the resistance.
- After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Refer to PRECAUTION [11/2021 - 10/2023]
- When disconnecting the cable from the negative (-) auxiliary battery
Refer to WORK PROCEDURE [10/2022 - ]
HINT:
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
HINT:
- When checking each connector, press the connector case in the direction of the connection before disconnecting the connectors, and check that there are no disconnections or looseness.
- When disconnecting the connectors, check that there is no damage, deformation, or corrosion of the connector terminals and connector case.
- Depending on the parts that are replaced, performing initialization, registration or calibration may be needed.
Refer to PRECAUTION [10/2022 - 10/2023]