Inspection [10/2017 - ]: Procedure
- INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
- Inspect the hazard warning signal switch assembly.
*a Component without harness connected
(Hazard Warning Signal Switch Assembly)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 6 - 3 Hazard warning signal switch OFF 10 kΩ or higher Hazard warning signal switch ON Below 50 Ω If the result is not as specified, replace the hazard warning signal switch assembly.
- Measure the resistance according to the value(s) in the table below.
- Check the illumination.
*a Component without harness connected
(Hazard Warning Signal Switch Assembly)
- Inspect the hazard warning signal switch assembly.