Inspection [10/2017 - 10/2020]: Procedure
- INSPECT REAR CORNER ULTRASONIC SENSOR (for LH Side)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O1-4 (BI) - O1-6 (EI) Always 10 kΩ or higher O1-4 (BI) - O1 -1 (BO) Always Below 1 Ω O1-5 (SI) - O1 -2 (SO) Always Below 30 Ω O1-6 (EI) - O1 -3 (EO) Always Below 1 Ω *a Component without harness connected (Rear Corner Ultrasonic Sensor) If the result is not as specified, replace the rear corner ultrasonic sensor.
- Measure the resistance according to the value(s) in the table below.
- INSPECT REAR CORNER ULTRASONIC SENSOR (for RH Side)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O4-4 (BI) - O4-6 (EI) Always 10 kΩ or higher O4-4 (BI) - O4-1 (BO) Always Below 1 Ω O4-5 (SI) - O4-2 (SO) Always Below 30 Ω O4-6 (EI) - O4-3 (EO) Always Below 1 Ω *a Component without harness connected (Rear Corner Ultrasonic Sensor) If the result is not as specified, replace the rear corner ultrasonic sensor.
- Measure the resistance according to the value(s) in the table below.
- INSPECT REAR CENTER ULTRASONIC SENSOR (for LH Side)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O2-4 (BI) - O2-6 (EI) Always 10 kΩ or higher O2-4 (BI) - O2-1 (BO) Always Below 1 Ω O2-5 (SI) - O2-2 (SO) Always Below 30 Ω O2-6 (EI) - O2-3 (EO) Always Below 1 Ω *a Component without harness connected (Rear Center Ultrasonic Sensor) If the result is not as specified, replace the rear center ultrasonic sensor.
- Measure the resistance according to the value(s) in the table below.
- INSPECT REAR CENTER ULTRASONIC SENSOR (for RH Side)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O3-4 (BI) - O3-6 (EI) Always 10 kΩ or higher O3-4 (BI) - O3-1 (BO) Always Below 1 Ω O3-5 (SI) - O3-2 (SO) Always Below 30 Ω O3-6 (EI) - O3-3 (EO) Always Below 1 Ω *a Component without harness connected (Rear Center Ultrasonic Sensor) If the result is not as specified, replace the rear center ultrasonic sensor.
- Measure the resistance according to the value(s) in the table below.