LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2020 >> LS 500 Base, RWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> HEADUP Display System - Diagnostic Codes & Circuit Tests >> HEADUP Display System >> Main Switch Circuit [10/2022 - 10/2023] >> Procedure

Main Switch Circuit [10/2022 - 10/2023]: Procedure

  1. READ VALUE USING TECHSTREAM (MAIN SWITCH) 
    1. Read the Data List according to the display on the Techstream.

      Body Electrical > Head Up Display > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Main Switch Integration control and panel assembly (headup display switch) status OFF or ON OFF: Switch released
      ON: Switch pushed
      -

      Body Electrical > Head Up Display > Data List 

      Tester Display
      Main Switch

      OK

      Integration control and panel assembly (headup display switch) condition displayed on the Techstream changes with the actual switch operation.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE METER MIRROR SUB-ASSEMBLY. Refer to  REMOVAL [10/2022 - 10/2023] 

    Result: 

    NG 

    See step  2

  2. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY 
    1. Remove the integration control and panel assembly (headup display switch).

      Refer to REMOVAL [12/2017 - ]

    2. Inspect the integration control and panel assembly (headup display switch).

      Refer to INSPECTION [10/2022 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE INTEGRATION CONTROL AND PANEL ASSEMBLY. Refer to  REMOVAL [12/2017 - ] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (METER MIRROR SUB-ASSEMBLY - INTEGRATION CONTROL AND PANEL ASSEMBLY [HEADUP DISPLAY SWITCH]) 
    1. Disconnect the G88 meter mirror sub-assembly connector.
    2. Disconnect the G6 integration control and panel assembly (headup display switch) connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      G88-9 (SW1) - G6-6 (ILU) Always Below 1 Ω
      G88-16 (E) - G6-18 (CH) Always Below 1 Ω
      G88-9 (SW1) or G6-6 (ILU) - Body ground Always 10 kΩ or higher
      G88-16 (E) or G6-18 (CH) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE METER MIRROR SUB-ASSEMBLY. Refer to  REMOVAL [10/2022 - 10/2023] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR