On-Vehicle Inspection [08/2015 - ]: Procedure
- CHECK BATTERY CONDITION NOTE:
If the battery is weak or if the engine is difficult to start, perform the following procedures.
- Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.
- Check the electrolyte quantity of each cell.
HINT:
Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).
- For maintenance-free batteries:
- If the electrolyte quantity is below the lower line, replace the battery.
- If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine. If the voltage is below 9.6 V, recharge or replace the battery.
- For non-maintenance-free batteries:
- If the electrolyte quantity is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte's specific gravity.
Standard specific gravity
1.25 to 1.29 at 20°C (68°F)
- If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine. If the voltage is below 9.6 V, recharge or replace the battery.
- If the electrolyte quantity is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte's specific gravity.
- For maintenance-free batteries:
- Turn the engine switch off and turn on the headlights for 20 to 30 seconds. This removes the surface charge from the battery.
- Measure the battery voltage between the negative (-) and positive (+) terminals of the battery.
Standard voltage
12.5 to 12.9 V at 20°C (68°F)
If the voltage is less than the specification, recharge the battery.
- INSPECT BATTERY TERMINAL AND FUSE
- Check that the battery terminals are not loose or corroded.
Positive (+) battery terminal
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) battery terminal
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
If the terminals are corroded, clean the terminals.
- Measure the resistance of the H-fuses and fuses.
Standard resistance
Below 1 Ω
If the result is not as specified, replace the fuses.
- Check that the battery terminals are not loose or corroded.
- INSPECT FAN AND GENERATOR V BELT
Refer to PROCEDURE - Step 1
- INSPECT GENERATOR WIRING
- Visually check the generator wiring.
- Check that the wiring is in good condition.
- Visually check the generator wiring.
- CHECK FOR ABNORMAL NOISES
- Listen for abnormal noises from the generator.
- Check that no abnormal noises are heard from the generator while the engine is running.
- Listen for abnormal noises from the generator.
- INSPECT CHARGE WARNING LIGHT CIRCUIT
- Turn the engine switch on (IG). Check that the charge warning light comes on.
- Start the engine and check that the light goes off.
If the light does not operate as specified, troubleshoot the charge warning light circuit.
- INSPECT CHARGING CIRCUIT WITHOUT LOAD
- Connect a voltmeter and ammeter to the charging circuit as follows.
- Disconnect the wire from terminal B of the generator, and then connect it to the negative (-) lead of an ammeter.TEXT IN ILLUSTRATION
*1 Battery *2 Terminal B *3 Generator - Connect the positive (+) lead of the ammeter to terminal B of the generator.
- Connect the positive (+) lead of a voltmeter to the positive (+) terminal of the battery.
- Ground the negative (-) lead of the voltmeter.
- Disconnect the wire from terminal B of the generator, and then connect it to the negative (-) lead of an ammeter.
- Check the charging circuit.
- Maintain the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.
Standard current
10 A or less
Standard voltage
13.2 to 14.8 V
If the voltmeter reading is higher than the standard voltage, replace the generator.
HINT:
If the battery is not fully charged, the ammeter reading will sometimes be higher than the standard current.
- Maintain the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.
- Connect a voltmeter and ammeter to the charging circuit as follows.
- INSPECT CHARGING CIRCUIT WITH LOAD
- With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the HI position.
- Check the reading on the ammeter.
Standard current
30 A or higher
If the ammeter reading is below the standard current, repair the generator.
HINT:
If the battery is fully charged, the indication will sometimes be below the standard current. If this is the case, add more electrical load (operate the wipers, rear window defogger, etc.) and check the reading on the ammeter again.