DTC C1ABE: Short to GND or Open in Buzzer [06/2018 - ]: Procedure
- READ VALUE USING TECHSTREAM (BLIND SPOT MONITOR SENSOR LH STATUS)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Blind Spot Monitor Slave / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Blind Spot Monitor Slave > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Buzzer Connection Status of the buzzer connection Valid or Invalid Valid: Buzzer connection is valid
Invalid: Buzzer connection is invalid- Slave Side RCTA Function Switches the RCTA function on and off OFF or ON OFF: RCTA function off
ON: RCTA function on- Body Electrical > Blind Spot Monitor Slave > Data List
Tester Display Buzzer Connection Slave Side RCTA Function Result
Result Proceed to "Valid" and "ON" is displayed for all items. A "Invalid" or "OFF" is displayed. B
Result:
B
REPLACE BLIND SPOT MONITOR SENSOR LH. Refer to REMOVAL [06/2018 - 08/2021] , or refer to REMOVAL [08/2021 - 09/2022] , or refer to REMOVAL [09/2022 - ]
Result:
A
See step 2
- CHECK DTC
- Turn the engine switch off.
- Turn the engine switch on (IG).
- Recheck for DTCs and check if the same DTC is output again.
Body Electrical > Blind Spot Monitor Slave > Trouble Codes
OK
No DTCs are output.
Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2018 - ]
Result:
NG
See step 3
- CHECK HARNESS AND CONNECTOR (RCTA BUZZER - BATTERY AND BLIND SPOT MONITOR SENSOR LH)
- Disconnect the N28 RCTA buzzer (blind spot monitor buzzer) connector.
- Disconnect the R5 blind spot monitor sensor LH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N28-2 (BZN) - R5-3 (BUZ) Always Below 1 Ω N28-2 (BZN) or R5-3 (BUZ) - Body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition N28-1 (BZP) - Body ground Engine switch on (IG) 11 to 14 V N28-1 (BZP) - Body ground Engine switch off Below 1 V Result
Proceed to OK NG
Result:
OK
REPLACE RCTA BUZZER (BLIND SPOT MONITOR BUZZER). Refer to REMOVAL [06/2018 - 08/2021] , or refer to REMOVAL [08/2021 - 09/2022] , or refer to REMOVAL [09/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR