Inspection [10/2014 - ]: Procedure
- INSPECT TRIP SWITCH (LIGHT CONTROL RHEOSTAT)
*1 Up Switch *2 Down Switch *a Component without harness connected
(Trip Switch (Light Control Rheostat))- Check the resistance.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 2 (RV) - 5 (E) Up switch on (Pushed) Below 1 Ω Up switch off (Not pushed) 10 kΩ or higher 2 (RV) - 5 (E) Down switch on (Pushed) 1.71 to 1.89 kΩ Down switch off (Not pushed) 10 kΩ or higher If the result is not as specified, replace the trip switch (light control rheostat).
- Check the illumination.
Apply battery voltage to the connector and check the illumination condition.
OK
Measurement Condition Specified Condition Battery positive (+) → Terminal 1 (ILL+)
Battery negative (-) → Terminal 3 (ILL-)Illuminates If the result is not as specified, replace the trip switch (light control rheostat).
*a Component without harness connected
(Trip Switch (Light Control Rheostat))
- Check the resistance.