Installation [08/2015 - ]: Procedure
- INSTALL FLYWHEEL HOUSING SIDE COVER
- INSTALL STARTER ASSEMBLY
- Install the starter with the 2 bolts.
Torque: 37 N*m (377 kgf*cm, 27 ft.*lbf)
- Connect the starter connector.
- Connect the starter wire with the nut.
Torque: 9.8 N*m (100 kgf*cm, 87 in.*lbf)
- Attach the starter wire clamp.
- Install the starter with the 2 bolts.
- INSTALL STARTER COVER
- Install the starter cover with the 3 bolts.
Torque: 12 N*m (117 kgf*cm, 8 ft.*lbf)
- Install the starter cover with the 3 bolts.
- INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY RH
(Refer to INSTALLATION [08/2015 - ] )
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Refer to INITIALIZATION [08/2015 - 08/2019] , or refer to INITIALIZATION [08/2019 - 08/2021] , or refer to INITIALIZATION [08/2021 - 08/2022] , or refer to INITIALIZATION [08/2022 - ] ).