DTC P0195-11: Engine Oil Temperature Sensor Circuit Short to Ground [06/2018 - 07/2019]: Description

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus ES 300h, 2023 Lexus ES 300h, 2022 Lexus ES 300h, 2021 Lexus ES 300h, and 2020 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.

A thermistor, whose resistance changes in accordance with the engine oil temperature, is built into the engine oil temperature sensor. As the engine oil temperature decreases, the thermistor resistance increases and as the engine oil temperature increases, the thermistor resistance decreases. The engine oil temperature sensor is connected to the ECM. A voltage of 5 V is supplied from terminal THEO via resistor R of the ECM. Since resistor R and the engine oil temperature sensor are connected in series, both the resistance and the electrical potential of THEO are subject to change in accordance with a change in the engine oil temperature.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P0195-11 Engine Oil Temperature Sensor Circuit Short to Ground The engine oil temperature sensor output voltage is less than 0.13 V for 5 seconds or more (1 trip detection logic).
  • Short in engine oil temperature sensor circuit
  • Engine oil temperature sensor
  • ECM
Comes on DTC stored SAE Code: P0197

HINT: 

When this DTC is output, check the engine oil temperature in the Data List. Enter the following menus: Powertrain / Engine / Data List / Engine Oil Temperature Sensor.

DTC No. Engine Oil Temperature Sensor Malfunction
P0195-11 Higher than 168°C (334°F) Short to ground in THEO circuit

If the Data List value is normal it may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.

Refer to CHECK FOR INTERMITTENT PROBLEMS [06/2018 - ]