Home >> Lexus >> 2019 >> ES 350 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 210 (Engine Cooling System (A25A-FKS) - Service Information) >> Thermostat >> Inspection [08/2020 - ] >> Procedure

Inspection [08/2020 - ]: Procedure

WARNING: This page is about a different car, the 2024 Lexus ES 250, 2023 Lexus ES 250, 2022 Lexus ES 250, and 2021 Lexus ES 250. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY 
    WARNING:
    • Do not put your hands into the water that has been heated for the inspection.
    • Touching the heated water could result in burns.
    GTY547274Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    HINT: 

    The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly.

    GTY753608Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
      NOTE:

      Do not allow any water to come into contact with the connector of the water inlet with thermostat sub-assembly.

    2. Check that the valve of the water inlet with thermostat sub-assembly opens at the specified temperature.

      Standard Valve Opening Temperature

      80 to 84°C (176 to 183°F)

      If the result is not as specified, replace the water inlet with thermostat sub-assembly.

    3. Check the valve lift.
      GTY752971Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Valve Lift

      Standard Valve Lift

      8.0 mm (0.315 in.) or more at 95°C (203°F)

      If the result is not as specified, replace the water inlet with thermostat sub-assembly.

    4. Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 72°C (162°F)).

      If it is not fully closed, replace the water inlet with thermostat sub-assembly.

    5. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 Always 10.6 to 14.2 Ω

      If the result is not as specified, replace the water inlet with thermostat sub-assembly.