LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2019 >> ES 350 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 147 (Engine Control System (A25A-FXS) - Diagnostic Codes (19 Of 20)) >> SFI System >> DTC P2681-11: Engine Coolant Bypass Valve Circuit Short to Ground; DTC P2681-15: Engine Coolant Bypass Valve Circuit Short to Battery or Open [06/2018 - 08/2020] >> Procedure

DTC P2681-11: Engine Coolant Bypass Valve Circuit Short to Ground; DTC P2681-15: Engine Coolant Bypass Valve Circuit Short to Battery or Open [06/2018 - 08/2020]: Procedure

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus ES 300h, 2023 Lexus ES 300h, 2022 Lexus ES 300h, 2021 Lexus ES 300h, and 2020 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK TERMINAL VOLTAGE (POWER SOURCE OF FLOW SHUTTING VALVE (FOR HEATER CONTROL)) 
    GTY811375Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    *a Front view of wire harness connector
    (to Water By-pass Hose Assembly)
    1. Disconnect the water by-pass hose assembly connector.
    2. Turn the power switch on (IG).
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      C69-2 - Body ground Power switch on (IG) 11 to 14 V

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI-MAIN NO. 1 RELAY - FLOW SHUTTING VALVE (FOR HEATER CONTROL)) 

    Result: 

    OK 

    See step  2

  2. INSPECT WATER BY-PASS HOSE ASSEMBLY 
    1. Inspect the water by-pass hose assembly.

      Refer to INSPECTION [06/2018 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE FLOW SHUTTING VALVE (FOR HEATER CONTROL) (WATER BY-PASS HOSE ASSEMBLY). Refer to  REMOVAL [06/2018 - 08/2020] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (FLOW SHUTTING VALVE (FOR HEATER CONTROL) - ECM) 
    1. Disconnect the water by-pass hose assembly connector.
    2. Disconnect the ECM connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      C69-1 - C88-42 (WSV1) Always Below 1 Ω
      C69-1 or C88-42 (WSV1) - Body ground and other terminals Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE ECM. Refer to  REMOVAL [06/2018 - 08/2020] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR