ALL
| Monitor runs whenever the following DTCs are not stored | None |
C12A6, C12BC, C12D2 AND C12E8 (CASE 1 AND 2)
| Serial communication with low side IC | Valid |
C12A7, C12BD, C12D3 AND C12E9
| All of the following conditions are met | - |
| Power supply for ABS solenoid | Higher than 9.13 V |
| Serial communication with low side IC | Valid |
| Output duty cycle | Higher than 40% |
| ABS holding solenoid current monitor | Normal |
| ABS solenoid power supply relay | On |
C12A8, C12B3, C12BE, C12C9, C12D4, C12DF, C12EA AND C12F5 (CASE 1)
| Both of the following conditions are met | - |
| Serial communication with low side IC | Valid |
| Current monitor power supply | Higher than 1.2 V, and less than 1.38 V |
C12A8, C12BE, C12D4 AND C12EA (CASE 2)
| All of the following conditions are met | - |
| Serial communication with low side IC | Valid |
| ABS solenoid power supply relay | On |
| Output duty cycle | 0% |
C12A8, C12BE, C12D4 AND C12EA (CASE 3)
| All of the following conditions are met | - |
| Serial communication with low side IC | Valid |
| Power supply for ABS solenoid | Higher than 9.13 V |
| Output duty cycle | 0% |
| ABS solenoid power supply relay | On |
C12B2, C12C8, C12DE AND C12F4
| All of the following conditions are met | - |
| ABS solenoid power supply relay | On |
| Serial communication with low side IC | Valid |
| Command to reduction solenoid on/off | On |
| ABS reduction solenoid current | Less than 4.4 A |
C12B3, C12C9, C12DF AND C12F5 (CASE 2)
| All of the following conditions are met | - |
| Serial communication with low side IC | Valid |
| ABS solenoid power supply relay | On |
| Command to reduction solenoid on/off | Off |
C12B3, C12C9, C12DF AND C12F5 (CASE 3)
| All of the following conditions are met | - |
| Serial communication with low side IC | Valid |
| Power supply for ABS solenoid | Higher than 9.13 V |
| Command to reduction solenoid on/off | Off |
| ABS solenoid power supply relay | On |