LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2019 >> ES 350 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 107 (Electronically Controlled Brake System (Hybrid) - Diagnostic Codes (1 Of 5)) >> ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model) >> DTC C1214: Hydraulic Control System Malfunction [06/2018 - 07/2019] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus ES 300h, 2023 Lexus ES 300h, 2022 Lexus ES 300h, 2021 Lexus ES 300h, and 2020 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
C139A (CASE 1)

Reaction force pressure 4.5 MPa (45.9 kgf/cm2 , 653 psi) or more
C139A (CASE 2)

Reaction force pressure 1.5 MPa (15.3 kgf/cm2 , 218 psi) or more
C139D

Servo pressure 0.1 MPa (1 kgf/cm2 , 15 psi) or less
C13CD (CASE 1)

Both of the following conditions are met -
Difference between target brake pressure and servo pressure Higher than 2.7 to 4.14 MPa (27.5 to 42.2 kgf/cm2 , 392 to 601 psi)
Delay of servo pressure increase Higher than 0.3 to 4.128 seconds
C13CD (CASE 2)

Both of the following conditions are met -
Difference between target brake pressure and servo pressure Higher than 1.5 MPa (15.3 kgf/cm2 , 218 psi)
Delay of servo pressure increase Higher than 0.3 to 4.128 seconds
C13CE (CASE 1 AND 2)

Both of the following conditions are met -
Difference between servo pressure and target brake pressure Higher than 1 to 4 MPa (10.2 to 40.8 kgf/cm2 , 145 to 580 psi)
Delay of servo pressure decrease Higher than 0.3 to 2.142 seconds
C13CE (CASE 3)

Difference between servo pressure and target brake pressure Higher than 0.5 MPa (5.1 kgf/cm2 , 73 psi)
C1400

All of the following conditions are met -
Servo pressure decrease (a) Higher than 0.4 MPa (4.1 kgf/cm2 , 58 psi)
Gradient of servo pressure (b) Less than -20 MPa/s
Servo pressure increase after ABS pump motor on after malfunction criteria (a) and (b) are met Higher than 0.5 MPa (5.1 kgf/cm2 , 73 psi)
Reduction of time required to ABS pump motor voltage drop below 1.3 V at ABS pump motor voltage on to off compared with no load condition after malfunction criteria (a) and (b) are met 0.1 seconds or more
C14EE AND C14F7

Either of the following conditions is met A or B
A. Both of the following conditions are met (a) and (b)
(a). Reaction force pressure decrease 0.03 MPa (0.3 kgf/cm2 , 4.4 psi) or more
(b). Reaction force pressure after malfunction criteria (a) is met 0.2 MPa (2 kgf/cm2 , 29 psi) or more
B. Both of the following conditions are met (c) and (d)
(c). Reaction force pressure Less than -0.6 MPa (-6.1 kgf/cm2 , -87 psi)
(d). Reaction force pressure after malfunction criteria (c) is met 0.2 MPa (2 kgf/cm2 , 29 psi) or more