Typical Malfunction Thresholds
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus ES 300h, 2023 Lexus ES 300h, 2022 Lexus ES 300h, 2021 Lexus ES 300h, and 2020 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
C13C1 AND C13CA
| One of the following conditions is met | A, B, C, D or E |
| A. Difference in monitor current (for solenoid control) and monitor current (for monitoring) | Higher than 0.281 A |
| B. Both of the following conditions are met | - |
| Current monitor value (for solenoid control) | 33 or less |
| Current | Less than 2.3 A |
| C. Both of the following conditions are met | - |
| Current monitor value (for monitoring) | 33 or less |
| Current | Less than 2.3 A |
| D. Reference voltage for current monitor circuit | 1.24 V or more, or 1.09 V or less |
| E. AC/DC converter built into CPU standard voltage | 4.4 V or less |
C14F2 AND C14FB
| One of the following conditions is met | A, B, C, D or E |
| A. Difference in monitor current (for solenoid control) and monitor current (for monitoring) | Higher than 0.294 A |
| B. Both of the following conditions are met | - |
| Current monitor value (for solenoid control) | 33 or less |
| Current | Less than 2.3 A |
| C. Both of the following conditions are met | - |
| Current monitor value (for monitoring) | 33 or less |
| Current | Less than 2.3 A |
| D. Reference voltage for current monitor circuit | 1.24 V or more, or 1.09 V or less |
| E. AC/DC converter built into CPU standard voltage | 4.4 V or less |
C13C2, C13CB, C14F3 AND C14FC (CASE 1)
| Solenoid current to output duty cycle relationship | Within the insufficient value judgment area in the following Map A |
C13C2, C13CB, C14F3 AND C14FC (CASE 2)
| Solenoid current to output duty cycle relationship | Within the insufficient value judgment area in the following Map B |
C13C2, C13CB, C14F3 AND C14FC (CASE 3)
| Solenoid high side voltage | Higher than 5.46 V |
C13C3, C13CC, C14F4 AND C14FD (CASE 1)
| Solenoid current to output duty cycle relationship | Within the excessive value judgment area in the following Map C |
C13C3, C13CC, C14F4 AND C14FD (CASE 2)
| Solenoid current to output duty cycle relationship | Within the excessive value judgment area in the following Map D |
C13C3, C13CC, C14F4 AND C14FD (CASE 3)
| Current | 0.15 A or more |
C13C3, C13CC, C14F4 AND C14FD (CASE 4)
| Current | Higher than 2.3 A |