Home >> Lexus >> 2019 >> ES 350 Luxury >> Repair and Diagnosis >> External Pages >> Different car >> Section 104 (Engine Control System (A25A-FKS) - Diagnostic Codes (02 Of 12)) >> SFI System >> DTC P0115-2A: Engine Coolant Temperature Sensor 1 Signal Stuck in Range [08/2020 - 08/2021] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2024 Lexus ES 250, 2023 Lexus ES 250, 2022 Lexus ES 250, and 2021 Lexus ES 250. However, it is still accessible from the selected car via links, so may be relevant.
COLD START MONITOR

All of the following conditions are met -
Battery voltage 10.5 V or higher
Time after engine start 1 second or more
Engine coolant temperature at engine start Less than 60°C (140°F)
Soak time 0 second or more
Accumulated mass air flow 4420 g or more
Engine Running
Fuel cut Off
Intake air temperature sensor circuit fail (P0112, P0113) Not detected
Engine coolant temperature sensor circuit fail (P0117, P0118) Not detected
Engine water pump circuit fail (P26CA, P26CC, P26CD) Not detected
Difference between engine coolant temperature at engine start and intake air temperature Less than 40°C (72°F)
SOAK MONITOR

All of the following conditions are met -
Battery voltage 10.5 V or higher
Engine Running
Soak time 5 hours or more
Either of the following conditions is met 1 or 2
1. Engine coolant temperature 60°C (140°F) or higher
2. Accumulated mass air flow 8840 g or more
Intake air temperature sensor circuit fail (P0112, P0113) Not detected
Engine coolant temperature sensor circuit fail (P0117, P0118) Not detected
Soak timer fail (P2610) Not detected
Engine water pump circuit fail (P26CA, P26CC, P26CD) Not detected