On-Vehicle Inspection [10/2015 - ]: Procedure
- INSPECT H-LP LH RELAY
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(H-LP LH Relay)Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the H-LP LH relay.
- Measure the resistance according to the value(s) in the table below.
- INSPECT H-LP RH RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the H-LP RH relay.
- Measure the resistance according to the value(s) in the table below.