Inspection [09/2017 - ]: Procedure
- INSPECT CLOCK ASSEMBLY
- Check the illumination.
Apply auxiliary battery voltage to the connector and check the illumination condition.
OK
Measurement Condition Specified Condition Auxiliary battery positive (+) → Terminal 6 (ILL+)
Auxiliary battery positive (+) → Terminal 1 (ILL-)
Auxiliary battery negative (-) → Terminal 2 (E)Illuminates If the result is not as specified, replace the clock assembly.
*a Component without harness connected
(Clock Assembly)