  1. INSPECT AIR CONDITIONING CONTROL ASSEMBLY (CLOCK) 
    1. Check the illumination.

      Apply battery voltage to the connector and check the illumination condition.

      OK

      Measurement Condition Specified Condition
      Battery positive (+) → Terminal 16 (ILL+)
      Battery negative (-) → Terminal 15 (ILL-)
      Illuminates

      If the result is not as specified, replace the air conditioning control assembly (clock).

      GTY498126Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component without harness connected
      (Air Conditioning Control Assembly (Clock))
  2. INSPECT HEATER CONTROL CABLE SUB-ASSEMBLY 
    1. Inspect the heater control cable sub-assembly.
      1. Measure the resistance and check the results in accordance with the value(s) in the tables below.
        GTY961913Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        *a Component without harness connected
        (Heater Control Cable Sub-assembly)
        *b Side with Printed Characters
        *c Side without Printed Characters - -

        Standard

        Tester Connection Specified Condition
        1-1 Below 1 Ω
        2-2 Below 1 Ω
        3-3 Below 1 Ω
        4-4 Below 1 Ω
        5-5 Below 1 Ω
        6-6 Below 1 Ω
        7-7 Below 1 Ω

        If the result is not as specified, replace the heater control cable sub-assembly.