DTC U11D0-87: Lost Local Communication with MET Missing Message; DTC U11D3-87: Lost Local Communication with Qi Missing Message [10/2023 - ]: Procedure
- CHECK FOR CAN BUS WIRE (MOBILE WIRELESS CHARGER CRADLE ASSEMBLY MAIN WIRE)
Pre-procedure1
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the G203 mobile wireless charger cradle assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G203-5(CANH) - G203-6(CANL) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE MOBILE WIRELESS CHARGER CRADLE ASSEMBLY. Refer to REMOVAL [10/2023 - ]
Result:
NG
See step 2
- CHECK FOR CAN BUS WIRE (RADIO RECEIVER ASSEMBLY MAIN WIRE)
Pre-procedure1
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the G186 radio receiver assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G186-11 (CNH1) - G186-12 (CNL1) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω G186-11 (CNH1) - G112-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher G186-12 (CNL1) - G112-4 (CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher G186-9(CNH2) - G186-10(CNL2) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω G186-9(CNH2) - G112-4(CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher G186-10(CNL2) - G112-4(CG) Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher G186-11 (CNH1) - G112-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher G186-12 (CNL1) - G112-16 (BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher G186-9(CNH2) - G112-16(BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher G186-10(CNL2) - G112-16(BAT) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
NG
REPLACE RADIO RECEIVER ASSEMBLY. Refer to REMOVAL [10/2022 - ]