Inspection [10/2015 - ]: Procedure
- INSPECT SOLENOID (SL1) VALVE
*a Component without harness connected
(Solenoid (SL1) Valve)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Connect a positive (+) lead with a 21 W bulb from the battery to terminal 1 and a negative (-) lead to terminal 2 of the solenoid (SL1) valve connector and check the operation of the valve.
OK
The valve moves and makes an operating sound.
If the result is not as specified, replace the solenoid (SL1) valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SOLENOID (SL2) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL3) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL4) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL5) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SLU) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SLT) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SC1) VALVE
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Solenoid (SC1) Valve)Standard Resistance
Tester Connection Condition Specified Condition Solenoid (SC1) valve connector terminal - Solenoid (SC1) valve body 20°C (68°F) 11 to 15 Ω - Connect a positive (+) lead from the battery to the terminal of the solenoid (SC1) valve connector, and a negative (-) lead to the solenoid (SC1) valve body, and check the operation of the valve.
OK
The valve moves and makes an operating sound.
If the result is not as specified, replace the solenoid (SC1) valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SOLENOID (SC2) VALVE
HINT:
Use the same procedure as for the solenoid (SC1) valve.
- INSPECT ELECTROMAGNETIC OIL PUMP (w/ Stop And Start System)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Electromagnetic Oil Pump)Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the result is not as specified, replace the electromagnetic oil pump.
- Measure the resistance according to the value(s) in the table below.